More Range of General Lab Testing Equipments:
Hot Air Oven
Conditioning Chamber
Muffle Furnace
Swatch Cutter
Lux Meter
DB. Meter
PH. Meter
Melting Point Apparatus
Weighting Scale
Water Bath
Moisture Meter
Dhona Balance
Product Details:
Minimum Order Quantity | 1 Unit |
Usage/Application | Laboratory |
Brand | Asian |
Material | Mild Steel |
Frequency (Hz) | 50 Hz |
Phase | Single Phase |
Voltage (V) | 220 V |
Country of Origin | Made in India |
Product Details:
Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Frequency | 50 Hz |
Brand | Asian |
Country of Origin | Made in India |
Power Source | Electric |
Traverse Speed | 5 -500 mm/min |
Testing Width | 390 mm |
Voltage | 220 V |
Additional Information:
Product Details:
Material | Mild Steel |
Automation Grade | Automatic |
Voltage | 220 V |
Display Type | Digital |
Brand | Asian |
Country of Origin | Made in India |
Usage/Application | Laboratory |
Surface Finish | Powder Coated |
Frequency: | 50 Hz |
Product Details:
Minimum Order Quantity | 1 Piece |
Frequency | 50 Hz |
Country of Origin | Made in India |
Power Source | Electric |
Brand | Asian |
Voltage | 220 V |
Weight | 90 Kg |
Asian Toxicity Chamber consists of an airtight enclosure of about 1 m³ volume lined with opaque plastic sheeting having a hinged, fitted with a transparent plastic panel. Some gaseous products of combustion may react with or be absorbed on the walls of the chamber. So the inner wall has the lining of polypropylene and with polycarbonate, transparency window is provided. The chamber is fitted with a vacuum pump forced air extraction system, which can be closed at the exit from the chamber when required.
The chamber is fitted with sampling positions such that the airtightness of the chamber is not impaired. The chamber is containing a mixing axial fan inside the chamber at horizontally and centrally inside the chamber at roof level to ensure rapid mixing of combustion products capable of being switched on and off externally.
The burner is to be capable of achieving a flame approximately 100 mm in height. The burner is fitted at the center of the chamber. There is a provision is to be made for igniting and extinguishing the burner from outside the chamber.
A digital temperature indicator is also mounted for the measurement of the temperature of the flame of the burner. The specimen support is an annulus cut from a sheet steel nominal thickness 2 mm of approximately 100 mm overall diameter with a 75 mm diameter hole carrying temperature resistance wires approximately 10 mm apart to form a lattice.
The complete assembly is equipped with a non-combustible side support arm to give a tennis racket appearance. This sample holder assembly has the provision of sliding of the sample without the leakage of the chamber.
There are two flow meters are fitted to the instrument to fine control of the supply of natural gas and air. All the parts are either polished or painted to give the corrosion resistance long life. Gas detection tubes and its pumps are optional which will be supplied at the separate order as per customer requirement.
Product Details:
Minimum Order Quantity | 1 Piece |
Melting Material | Lab |
Power Source | Electric |
Type Of Furnace | Fix |
Max Temperature ( C) | 800-900 Degree Celsius, 1000-1100 Degree Celsius |
Type Of Model | Laboratory |
Voltage | 220 V |
Brand | Asian |
Country of Origin | Made in India |
Heating Rate | 0~10.C/min |
Frequency | 50/60 Hz |
Phase | Single Phase |
Material | Mild Steel |
Product Details:
Usage/Application | Industrial Use |
Material | Mild Steel |
Power Source | Electric |
Voltage | 220 V |
Brand | Asian |
Country of Origin | Made in India |
Frequency | 50 Hz |
Surface Finish | Powder Coated |
Product Details:
Minimum Order Quantity | 1 Piece |
Material | Mild Steel |
Frequency | 50 Hz |
Brand | Asian |
Country of Origin | Made in India |
Voltage | 220 V |
Input Pressure | 0.2-0.3 Mpa |
Power Source | Electric |
Oxygen Index Apparatus is defined as minimum concentration of oxygen, expressed as volume percent in a mixture of oxygen and nitrogen that just support flaming combustion of plastic materials under equilibrium condition of candle like burning. The equilibrium is established by the relation between the net lost to the surroundings as measured by either time of burning or length of specimen burned. This point is approached from both sides of the critical oxygen concentration in order to establish the oxygen index.
Product Details:
Minimum Order Quantity | 1 Unit |
Brand | Asian |
Power Source | Electric |
Number Of Heaters | 2 |
Phase | Single |
Automation Grade | Automatic |
Country of Origin | Made in India |
Voltage | 220 V |
Frequency | 50 Hz |
Light Source: Fluorescent UV B type lamp with wavelength of 313nm
UV Lamps: 40W, 8Nos.
Black Panel temperature range: Ambient to 90°C
Black Panel temperature control: +/- 2°C
Water/Condensation temp range: Ambient to 90°CTest Capacity: Provision of holding 22 specimen of size 75 × 300mm
RELATED STANDARD:
ASTM G53, ASTM D4329, ASTM D5208, ISO 4892 IS 14887 : 2000 and meets other relevant National and International test standards.
Product Details:
Usage/Application | Industrial |
Brand | Asian |
Country of Origin | Made in India |
Display Type | Digital |
Weight | 10.5 Kg |
Using our years of experience and with the support of our diligent team of professionals, we are instrumental in providing quality assured Moisture Meter.